PRODUCTS
EShop-number
Password
Welcome to SK Sales
 

EWYT-CZ • Heat Pump

Brand

Daikin

Product

DAIKIN R-32 SCROLL INVERTER CHILLER EWYT-CZ

Application

The Daikin R-32 Small Inverter Chiller EWYT-CZ is an air-cooled scroll chiller and heat pump for small to medium-size buildings, able to cover both comfort cooling and process cooling needs

Advantage

  • Full Inverter technology
  • Wide operating range: from – 20 °C up to 46 °C in cooling mode and from 20 °C to 35 °C in heating mode
  • High temperature kit available to extend operating limits up to 52 °C
  • Hot sanitary water up to 60 °C
  • Best efficiency levels in the market
  • Lowest direct and indirect CO2 emissions in the market
  • Silent operations
  • Mater/Slave function as standard
  • Available with Inverter Pump Kit both Low and High Lift
  • Optional advanced connectivity kit including: connectivity to any BMS, Daikin on Site and the Daikin App for fast commissioning

Refrigerant

R32

Features

  • Cooling capacity range: 16 – 90 kW
  • Heating capacity range : 16 – 90 kW
  • EER: up to 3.16
  • SEER: up to 5.41
  • COP: up to 3.41
  • SCOP: up to 4.19
  • Daikin in-house built scroll compressor with inverter technology
  • 1 or 2 refrigerant circuits
  • Optimized brazed plate heat exchanger
  • Optimized Copper-Aluminum condensing coil

Video 1

Specifications

ModelEWYT016CZNEWYT021CZNEWYT025CZNEWYT032CZNEWYT040CZN
Cooling capacityNom.  kW15.920.925.632.441.4
Heating capacityNom.  kW15.920.224.832.440.3
Capacity controlMethod   Inverter controlledInverter controlledInverter controlledInverter controlledInverter controlled
 Minimum capacity  %1814121914
Power inputCooling Nom.kW5.506.608.5010.313.2
 Heating Nom.kW4.705.807.509.4011.9
EER    2.903.163.003.133.12
COP    3.413.463.333.453.38
DimensionsUnit Depthmm802802802802814
   Heightmm1,8781,8781,8781,8781,878
   Widthmm1,1521,1521,1521,7522,306
WeightOperation weight  kg228254254353500
 Unit  kg227252252350494
Water heat exchangerType   Braze plate heat exchangerBraze plate heat exchangerBraze plate heat exchangerBraze plate heat exchangerBraze plate heat exchanger
 Water volume  l12225
Air heat exchangerType   High efficiency fin and tube typeHigh efficiency fin and tube typeHigh efficiency fin and tube typeHigh efficiency fin and tube typeHigh efficiency fin and tube type
FanSpeed  rpm800800900700700
CompressorQuantity   11112
 Type   Scroll compressorScroll compressorScroll compressorScroll compressorScroll compressor
Sound power levelCooling Nom.dBA76.076.078.079.080.0
Sound pressure levelCooling Nom.dBA59.759.761.762.262.8
RefrigerantType   R-32R-32R-32R-32R-32
 GWP   675675675675675
 Circuits Quantity 11112
 Charge  kg3.005.505.507.0012.0
Piping connectionsWater heat exchanger inlet / outlet   1''1/41''1/41''1/41''1/42''
Space heatingAverage climate water outlet 55°C GeneralSCOP 2.832.892.852.93
   Seasonal space heating eff. class  A+A+A+A+
   ηs (Seasonal space heating efficiency)% 110113111114
 Average climate water outlet 35°CGeneralSCOP 3.894.004.074.064.02
   Seasonal space heating eff. class A++A++A++A++A++
   ηs (Seasonal space heating efficiency)%153157160159158
Notes    (1) - Cooling: EW 12°C; LW 7°C; ambient conditions: 35°CDB
     (2) - Cooling: EW 23°C; LW 18°C; ambient conditions: 35°CDB
     (3) - Condition: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C)
     (4) - Condition: Ta DB/WB 7°C/6°C - LWC 45°C (Dt=5°C)
     (5) - According to EN14825
     (6) - Depends on operation mode, refer to installation manual.
     (7) - For more details, see operation range drawing

Specifications

ModelEWYT040CZNEWYT050CZNEWYT064CZNEWYT090CZN
Cooling capacityNom.  kW39.650.864.088.3
Heating capacityNom.  kW39.449.861.985.8
Capacity controlMethod   Inverter controlledInverter controlledInverter controlledInverter controlled
 Minimum capacity  %15121514
Power inputCooling Nom.kW13.417.021.831.0
 Heating Nom.kW11.815.419.127.2
EER    2.952.982.932.84
COP    3.333.243.233.16
DimensionsUnit Depthmm802814814814
   Heightmm1,8781,8781,8781,878
   Widthmm1,7522,3062,9063,506
WeightOperation weight  kg352500594701
 Unit  kg349494588693
Water heat exchangerType   Braze plate heat exchangerBraze plate heat exchangerBraze plate heat exchangerBraze plate heat exchanger
 Water volume  l2558
Air heat exchangerType   High efficiency fin and tube typeHigh efficiency fin and tube typeHigh efficiency fin and tube typeHigh efficiency fin and tube type
FanSpeed  rpm900900800900
CompressorQuantity   1222
 Type   Scroll compressorScroll compressorScroll compressorScroll compressor
Sound power levelCooling Nom.dBA80.081.083.085.0
Sound pressure levelCooling Nom.dBA63.263.865.467.0
RefrigerantType   R-32R-32R-32R-32
 GWP   675675675675
 Circuits Quantity 1222
 Charge  kg8.0012.013.016.0
Piping connectionsWater heat exchanger inlet / outlet   1''1/42''2''2''
Space heatingAverage climate water outlet 55°C GeneralSCOP2.892.922.902.89
   Seasonal space heating eff. class A+A+A+A+
   ηs (Seasonal space heating efficiency)%113114113113
 Average climate water outlet 35°CGeneralSCOP 4.074.003.984.00
   Seasonal space heating eff. class A++A++A++A++
   ηs (Seasonal space heating efficiency)%160157156157
Notes    (1) - Cooling: EW 12°C; LW 7°C; ambient conditions: 35°CDB
     (2) - Cooling: EW 23°C; LW 18°C; ambient conditions: 35°CDB
     (3) - Condition: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C)
     (4) - Condition: Ta DB/WB 7°C/6°C - LWC 45°C (Dt=5°C)
     (5) - According to EN14825
     (6) - Depends on operation mode, refer to installation manual.
     (7) - For more details, see operation range drawing
Mobile WebsiteAbout UsDisclaimerPrivacy policyCookie policy

Requesting information. Please wait a moment...