PRODUCTS
EShop-number
Password
Welcome to SK Sales
 

FXFA-A • VRV - Round Flow Cassette

F-Gas Certified

To be able to purchase this product we must hold a copy of your company F-Gas Certification on your account.

Links to accepted certification

REFCOM

F-Gas

  • Daikin

Product

Round flow cassette


360° air discharge for optimum efficiency and comfort

Application

  • Cooling or Heating

Advantage

  • Optimised design for R-32 refrigerant
  • Optional automatic filter cleaning panel results in higher efficiency & comfort and lower maintenance costs.
  • Two optional intelligent sensors improve energy efficiency and comfort
  • Widest choice ever in decoration panels: designer panels in white (RAL9010) and black (RAL9005) and standard panels in white (RAL9010) with grey louvers or full white
  • Bigger flaps and unique swing pattern improve equal air distribution
  • Individual flap control: flexibility to suit every room layout without changing the location of the unit!
  • Lowest installation height in the market: 214mm for class 20-63
  • Optional fresh air intake
  • Standard drain pump with 675mm lift increases flexibility and installation speed

Refrigerant

  • R32

Features

  • Onecta app (optional) (optional)

    Control your indoor climate from any location via smartphone or tablet

  • Presence & floor sensor (optional)

    The presence sensor directs the air away from any person detected in the room, when the air flow control is on. The floor sensor detects the average floor temperature and ensures an even temperature distribution between ceiling and floor.

  • Home leave operation

    Maintains the indoor temperature at your specified comfort level during absence, thus saving energy

  • Fan only

    The unit can be used as fan, blowing air without heating or cooling.

  • Draught prevention

    When starting to warm up or when the thermostat is off, the air discharge direction is set horizontally and the fan to low speed, to prevent draught. After warming up, air discharge and fan speed are set as desired.

  • Auto cooling-heating changeover

    Automatically selects heating or cooling mode to achieve the set temperature.

  • Whisper quiet

    Daikin indoor units are whisper quiet. Also the outdoor units are guaranteed not to disturb the quiet of the neighbourhood.

  • Ceiling soiling prevention

    Prevents air from blowing out too long in horizontal position, to prevent ceiling stains.

  • Individual flap control

    Individual flap control via the wired remote controller enables you to easily fix the position of each flap individually, to suit any new room configuration. Optional closure kits are available as well.

  • Vertical auto swing

    Possibility to select automatic vertical moving of the air discharge flaps for efficient air and temperature distribution throughout the room.

  • Fan speed steps (5 steps + auto)

    Allows to select up to the given number of fan speed.

  • Dry programme

    Allows humidity levels to be reduced without variations in room temperature.

  • Air filter (pre filter)

    Removes airborne dust particles to ensure a steady supply of clean air.

  • Weekly timer

    Can be set to start heating or cooling anytime on a daily or weekly basis.

  • Infrared remote control (optional - must be combined with Madoka wired remote controller)

    Starts, stops and regulates the air conditioner from a distance.

  • Wired remote control (required option)

    Starts, stops and regulates the air conditioner.

  • Centralised control (optional)

    Starts, stops and regulates several air conditioners from one central point.

  • Auto-restart

    The unit restarts automatically at the original settings after power failure.

  • Self diagnosis

    Simplifies maintenance by indicating system faults or operating anomalies.

  • Multi tenant

    The indoor unit's main power supply can be turned off when leaving the hotel or office building.

  • Drain pump kit (standard)

    Facilitates condensation draining from the indoor unit.

  • Auto-cleaning filter (optional)

    The filter automatically cleans itself. Simplicity of upkeep means optimum energy efficiency and maximum comfort without the need for expensive or time-consuming maintenance.

Applicable outdoor units

Applicable outdoor units
  • Type RXYSA 4/5/6 AV1
  • Type RXYSA 4/5/6 AY1
  • Type REYA 8/10/12/14/16/18/20 A
  • Type REMA5-A (Multi Only)

Specifications

Indoor UnitsFXFA20AFXFA25AFXFA32AFXFA40AFXFA50AFXFA63AFXFA80AFXFA100AFXFA125A
CapacityUK Total Cooling kW1.62.12.73.34.15.26.58.210.3
UK Sensible Cooling kW1.31.72.12.63.13.956.48
Nominal Cooling kW2.22.83.64.55.67.1911.214
Nominal Heating kW2.53.2456.381012.516
Air Flow RateHigh m3/sec0.2130.2130.2130.2470.2520.2770.3880.480.55
Nom m3/sec0.1780.1780.1780.210.2130.2220.3220.3530.457
Low m3/sec0.1480.1480.1480.1730.1780.1780.230.230.343
Dimensions Height x Width x Depth mm204x840x840246x840x840288x840x840
Weight kg181818192121242426
Standard Decoration PanelsModelRoundflow BYCQ140E white (standard panel) / Roundflow BYCQ140EB black
ColourPure White (RAL 9010) / Black (RAL9005)
Dimensions H x W x D mm65x950x950
Weight kg5.5
Fully White Decoration PanelModelRoundflow with white louvres BYCQ140EW
ColourPure White (RAL 9010)
Dimensions H x W x D mm65x950x950
Weight kg5.5
Self Cleaning Decoration PanelsModelRoundflow self-cleaning BYCQ140EGF white / Roundflow self-cleaning BYCQ140EGFB black
ColourPure White (RAL 9010) / Black (RAL9005)
Dimensions H x W x D mm148x950x950
Weight kg10.3
Electrical DetailsRunning Current amps0.20.20.20.20.30.30.50.71.2
Power Supply Phase / Hz / V1 / 50 / 230
Fuse Rating amps6
Sound LevelSound PressureHigh dBA313131333335384345
Nom dBA292929313133343741
Low dBA282828292930303036
Sound Power dBA494949515153556061
Piping ConnectionsLiquid inch (mm)1/4 (6.4)1/4 (6.4)1/4 (6.4)1/4 (6.4)1/4 (6.4)1/4 (6.4)1/4 (6.4)3/8 (9.5)3/8 (9.5)
Gas inch (mm)3/8 (9.5)3/8 (9.5)3/8 (9.5)1/2 (12.7)1/2 (12.7)1/2 (12.7)1/2 (12.7)5/8 (15.9)5/8 (15.9)

Dimensions

Installation

Mobile WebsiteAbout UsDisclaimerPrivacy policyCookie policy