The Daikin optional electrical heater for the VAM units mean that the VAM's
can be installed practically anywhere. The operation range is extended down to -20°CDB
Total fresh air solution with optional electrical heater
- Increased comfort in low outdoor temperatures thanks to the heated outdoor air
- Integrated electrical heater concept (no additional accessories required)
- Standard dual flow and temperature sensor
- Flexible setting with adjustable setpoint
- Increased safety with 2 cut-outs: manual & automatic
- Plug and play electrical heater for Daikin VAM-J and VAM-FC units
- Easier connectivity
- Revised delivered power
- Heater control through PWM
- Automatic and manual safety cut out
- Flow sensor for additional safety
Heater InstallationKeep a minimum of 2 meters of duct from the heater to the VAM unit.
Combination opportunities
|
| VAM150FC | GSIEKA10009 | | VAM250FC | GSIEKA15018 | | VAM350J | GSIEKA20024 | | VAM500J | GSIEKA20024 | | VAM650J | GSIEKA25030 | | VAM800J | GSIEKA25030 | | VAM1000J | GSIEKA25030 | | VAM1500J (without plenum) | GSIEKA25030 | | VAM1500J (with plenum) | GSIEKA35530 | | VAM2000J (without plenum) | GSIEKA25030 | | VAM2000J (with plenum) | GSIEKA35530 |
Specifications
|
| Dimensions | Height | mm | 171 | 221 | 271 | 321 | 426 | | Width | mm | 370 | 370 | 370 | 370 | 373 | | Depth | mm | 100 | 150 | 200 | 250 | 355 | | Minimum air velocity / airflow | m/s | 1.5 | | m3/s | 0.01 | 0.02 | 0.04 | 0.07 | 0.14 | | Power supply | 1~230 VAC/50Hz | | Nominal current | A | 4.1 | 8.2 | 10.9 | 13.1 | 13.1 | | Heating power | kW | 0,9 | 1,8 | 2,4 | 3,0 | 3,0 | | Connection duct diameter | mm | 100 | 150 | 200 | 250 | 355 | | Operation range | Min. | °C | -40°C | | Max. | °C | 40°C | | Rel. Humidity % | 0.9 | | Temperature sensor | 10 kΩ at +25°C / TJ-K10K | | Temperature sensor range | - 30°C to 105°C | | Temperature set point range | - 10°C to 50°C | | LED indicators | LED 1 | flashing every 5 seconds | heater is starting up | | flashing every second | air flow detected, heating allowed | | OFF | no power supply or no flow | | ON | problem with duct temperature sensor, set point potentiometer or PTC airflow sensor | | LED 2 | OFF | heater is not operation | | ON | heater is operating | | Ambient temperature adjacent to controller | 0°C to +50°C | | Auto high temperature cut-out | 50°C | | Manual reset high temperature cut-out | 100°C |
Dimensions
Dimensions
|
| GSIEKA10009 | 370 | 276 | 71 | 100 | | GSIEKA15018 | 370 | 276 | 71 | 150 | | GSIEKA20024 | 370 | 276 | 71 | 200 | | GSIEKA25030 | 370 | 276 | 71 | 250 | | GSIEKA35530 | 373 | 276 | 71 | 355 |
|