Indoor unit has Daikin P1/P2 & F1/F2 connectivity.
BRC1D52 - Hard wired controller (old style)
BRC1E53A - Hard wired controller
BRC1H52W - Madoka controller in White
BRC1H52S - Madoka controller in Silver
BRC1H52K - Madoka controller in Black
KRP2A52 - System adaptor PCB for remote on/off, status indication and temperature setting
RTD-Net - Modbus Interface PCB for Sky Air and VRV
RTD-20 - Energy control PCB for Sky Air and VRV
BRP4A50 - PCB Adaptor for VAM-FC series connection to 3rd party heater
KRP50-2 - PCB Adaptor for VAM-FC series connection to humidifier
Specifications
| VAM150FC9 | VAM250FC9 | Power input - 50Hz | Heat exchange mode | Nom. | Ultra high | kW | 0.132 | 0.161 | | | | High | kW | 0.111 | 0.079 | | | | Low | kW | 0.058 | 0.064 | | Bypass mode | Nom. | Ultra high | kW | 0.132 | 0.161 | | | | High | kW | 0.111 | 0.079 | | | | Low | kW | 0.058 | 0.064 | Casing | Material | | | | Galvanised steel plate | Galvanised steel plate | Insulation material | | | | | Self-extinguishable urethane foam | Self-extinguishable urethane foam | Dimensions | Unit | | Height | Mm | 285 | 285 | | | | Width | Mm | 776 | 776 | | | | Depth | Mm | 525 | 525 | Weight | Unit | | | kg | 23.0 | 23.0 | Fan | Type | | | | Sirocco fan | Sirocco fan | | Air flow rate - 50Hz | Heat exchange mode | Ultra high | m³/h | 150 | 250 | | | | High | m³/h | 140 | 230 | | | | Low | m³/h | 105 | 155 | | | Bypass mode | Ultra high | m³/h | 150 | 250 | | | | High | m³/h | 140 | 230 | | | | Low | m³/h | 105 | 155 | | External static pressure - 50Hz | | Ultra high | Pa | 90.0 | 70.0 | | | | High | Pa | 87.0 | 63.0 | | | | Low | Pa | 40.0 | 25.0 | Fan motor | Quantity | | | | 2 | 2 | | Output | | 50 Hz | W | 30 | 30 | Temperature exchange efficiency - 50Hz | Ultra high | | | % | 77.0 , 72.0 | 74.9 , 69.5 | | High | | | % | 78.3 , 72.3 | 76.0 , 70.0 | | Low | | | % | 82.8 , 73.2 | 80.1 , 72.0 | Enthalpy exchange efficiency - 50Hz | Cooling | | Ultra high | % | 60.3 | 60.3 | | | | High | % | 61.9 | 61.2 | | | | Low | % | 67.3 | 64.5 | | Heating | | Ultra high | % | 66.6 | 66.6 | | | | High | % | 67.9 | 67.4 (2) | | | | Low | % | 72.4 | 70.7 | Operation range | Min. | | | °CDB | -15 | -15 | | Max. | | | °CDB | 50 | 50 | | Relative humidity | | | % | 80 or less | 80 or less | Sound pressure level - 50Hz | Heat exchange mode | | Ultra high | dBA | 27.0 | 28.0 | | | | High | dBA | 26.0 | 26.0 | | | | Low | dBA | 20.5 | 21.0 | | Bypass mode | | Ultra high | dBA | 27.0 | 28.0 | | | | High | dBA | 26.5 | 27.0 | | | | Low | dBA | 20.5 | 21.0 | Heat exchange system | | | | | Air to air cross flow total heat (sensible + latent heat) exchange | Air to air cross flow total heat (sensible + latent heat) exchange | Heat exchange element | | | | | Specially processed non-flammable paper | Specially processed non-flammable paper | Air filter | Type | | | | Multidirectional fibrous fleeces | Multidirectional fibrous fleeces | Connection duct diameter | Mm | | | | 100 | 150 | Operation mode | | | | | Heat exchange mode, bypass mode, fresh-up mode | Heat exchange mode, bypass mode, fresh-up mode | General | Supplier/Manufacturer details | | Name or trademark | | Daikin Europe N.V. | Daikin Europe N.V. | | Product description | | Model identifier | | VAM150FCVE | VAM250FCVE | Specific energy consumption (SEC) | Cold climate | | | kWh/(m².a) | -65.4 | -65.1 | | Average climate | | | kWh/(m².a) | -27.1 | -29.2 | | Warm climate | | | kWh/(m².a) | -2.51 | -6.10 | SEC class | | | | | B | B | Type of product | | | | | Bidirectional RVU | Bidirectional RVU | Type of drive | | | | | Multi-speed drive | Multi-speed drive | Heat recovery system | | | | | recuperative | recuperative | Thermal efficiency | % | | | | 89.1 (3) | 80.4 (3) | Maximum flow rate at 100 Pa ESP | Flow rate | | | m³/h | 130 | 207 | | Electric power input | | | W | 129 | 160 | Sound power level (Lwa) | dB | | | | 40 | 43 | Reference flow rate | m³/s | | | | 0.025 | 0.035 | Reference pressure difference | Pa | | | | 50.0 | 50.0 | Specific power input | W/(m³/h) | | | | 0.616 | 0.454 | Ventilation control | Type | | | | Clock control | Clock control | | Factor | | | | 0.95 | 0.95 | Maximum external leakage | % | | | | 7.42 | 4.66 | Maximum internal leakage | % | | | | 4.50 | 4.50 | Annual electricity consumption | kWh/a | | | | 18.6 | 13.8 | Annual heating saved | Cold climate | | | kWh/a | 45.7 | 43.1 | | Average climate | | | kWh/a | 89.4 | 84.3 | | Warm climate | | | kWh/a | 20.7 | 19.5 | Power supply | Name | | | | VE | VE | | Phase | | | | 1~ | 1~ | | Frequency | | | Hz | 50/60 | 50/60 | | Voltage | | | V | 220-240/220 | 220-240/220 | Voltage range | Min. | | | % | -10 | -10 | | Max. | | | % | 10 | 10 | Current | Minimum circuit amps (MCA) | | | A | 0.900 | 0.900 | | Maximum fuse amps (MFA) | | | A | 15.0 | 15.0 | | Fan motor rated output | | | kW | 0.03x2 | 0.03x2 | | Full load amps (FLA) | | Fan motor | A | 0.400 | 0.400 | | | | Fan motor 2 | A | 0.400 | 0.400 |
Dimensions
Dimensions
|