SK Sales Ltd uses cookies and other techniques on the website www.sksales.co.uk. When you visit the SK Sales website, we can collect and / or store information about your visit. Cookies are small information files that are stored when you visit the website on the device with which you visit our website, such as a computer, tablet, smartphone or smartwatch.
 

Under Ceiling Cassette FUA-A • Daikin Under Ceiling Cassette Indoor Unit

F-Gas Certified

To be able to purchase this product we must hold a copy of your company F-Gas Certification on your account.

Links to accepted certification

REFCOM

F-Gas

Brand

  • Daikin

Product

  • Under Ceiling Cassette - Sky-Air - Indoor Unit

Application

  • Cooling or Heating

Advantage

  • Even rooms with ceilings up to 3.5m can be heated up or cooled down very easily without capacity loss
  • Can easily be installed in both new and refurbishment projects
  • Unified indoor unit range for R-32 and R-410A
  • Combining with R-32 Bluevolution technology, reduces environmental impact with 68% compared to R-410A, leads directly to lower energy consumption thanks to its high energy efficiency and has up to lower 16% refrigerant charge
  • Individual flap control: flexibility to suit every room layout without changing the location of the unit!
  • 5 different discharge angles between 0 and 60┬░can be programmed via the remote control
  • Stylish modern casing finished in pure white (RAL9010) and iron grey (RAL7011) blends easily with any interior
  • Optimum comfort guaranteed with automatic air flow adjustment to the required load
  • Standard drain pump with 720mm lift increases flexibility and installation speed

Function

  • Air-2-Air, Heatpump, Inverter Driven

Refrigerant

  • R32

Features

  • Home leave operation

    Maintains the indoor temperature at your specified comfort level during absence, thus saving energy

  • Fan only

    The unit can be used as fan, blowing air without heating or cooling.

  • Draught prevention

    When starting to warm up or when the thermostat is off, the air discharge direction is set horizontally and the fan to low speed, to prevent draught. After warming up, air discharge and fan speed are set as desired.

  • Auto cooling-heating changeover

    Automatically selects heating or cooling mode to achieve the set temperature.

  • Individual flap control

    Individual flap control via the wired remote controller enables you to easily fix the position of each flap individually, to suit any new room configuration. Optional closure kits are available as well.

  • Vertical auto swing

    Possibility to select automatic vertical moving of the air discharge flaps for efficient air and temperature distribution throughout the room.

  • Fan speed steps (5 steps)

    Allows to select up to the given number of fan speed.

  • Dry programme

    Allows humidity levels to be reduced without variations in room temperature.

  • Air filter

    Removes airborne dust particles to ensure a steady supply of clean air.

  • Weekly timer

    Can be set to start heating or cooling anytime on a daily or weekly basis.

  • Infrared remote control (optional)

    Starts, stops and regulates the air conditioner from a distance.

  • Wired remote control (optional)

    Starts, stops and regulates the air conditioner.

  • Centralised control (optional)

    Starts, stops and regulates several air conditioners from one central point.

  • Online controller via app

    Control your indoor unit from any location via app

  • Auto-restart

    The unit restarts automatically at the original settings after power failure.

  • Self diagnosis

    Simplifies maintenance by indicating system faults or operating anomalies.

  • Drain pump kit (standard)

    Facilitates condensation draining from the indoor unit.

  • Twin/triple/double twin application

    2,3 or 4 indoor units can be connected to only a single outdoor unit even if they have different capacities. All indoor units operate within the same heating or cooling mode from one remote control.

  • Infrastructure cooling (standard)

    Remove in a reliable, efficient and flexible way the heat constantly generated by the IT and server equipment to ensure maximum uptime while offering the best return on investment.

Applicable outdoor units

  • Type RZAG 71/100/125 NV1/NY1
  • Type RZASG 71/100/125 MV1
  • Type RZASG 100/125 MY1
  • Type RZA 200/250 D (Twin/Triple only)

V1 = 1PH & Y1 = 3PH

Applicable controller

Indoor unit has Daikin P1/P2 & F1/F2 connectivity.

BRC1D52 - Hard wired controller (old style)
BRC1E53A - Hard wired controller
BRC1H519W7 - Madoka controller in White
BRC1H519S7 - Madoka controller in Silver
BRC1H519K7 - Madoka controller in Black
BRC7EB518 - Infra-Red wireless controller
BRP069A81 - Wifi adaptor for connection to on-line controller
BRC7C58 - Wireless remote controller
EKRORO5 - Remote on/off control interface kit

Accessories

KLIC-DI - KNX Interface for Sky Air and VRV systems
KRCS01-4 - Remote room mounted temperature sensor
KDDQ50A140 - Fresh air intake kit for up to 20% fresh air
KRP4A53 and UK.FB2 - Unit/group adaptor PCB for remote on/off, status indication and temperature setting
K.RSS - Wireless room mounted temperature sensor and receiver
RS-SE - Service and configuration tool for K.RSS
RTD-10 and UK.FB2 - Enhanced function PCB for Sky Air and VRV. Duty rotation, Lead Lag control and heating interlock
RTD-20 and UK.FB2 - Energy control PCB for Sky Air and VRV
RTD-NET and UK.FB2 - Modbus interface PCB for Sky Air and VRV
UK.FB2 - Mounting Box

Specifications

Indoor Units    FUA71AFUA100AFUA125A
CapacityUK Total Cooling kW7.7610.813.6
UK Sensible Cooling kW5.327.449.3
Nominal Cooling kW6.89.512.1
Nominal Heating kW7.510.813.5
Seasonal Efficiency (EN14825) COOLINGEnergy LabelA++A+-
Pdesign kW6.89.512.1
SEER6.165.835.27
Annual Energy Consumption kWh3865701378
Seasonal Efficiency (EN14825) HEATINGEnergy LabelAA+-
Pdesign kW4.566
SCOP3.94.013.84
Annual Energy Consumption kWh161520952188
Nominal EfficiencyEER/COP 3.84/3.893.20/4.922.35/4.00
Air Flow Rate (Cooling)High / Nom / Lowm3/sec0.383/0.325/0.2660.516/0.425/0.3330.541/0.441/0.341
DimensionsHeight mm198198198
Width mm950950950
Depth mm950950950
Weight kg252626
Sound Pressure (Cooling)High / Nom / LowdBA41/38/3546/42/3947/43/40
Sound Pressure (Heating)High / Nom / LowdBA41/38/3546/42/3947/43/40
Sound Power (Cooling) dBA596465

Dimensions

Installation

Cookie policyProductsContact usJoin our teamAbout our companyPrivacy policyDisclaimer