To be able to purchase this product we must hold a copy of your company F-Gas Certification on your account.
Links to accepted certification
Specifications
|
| Dimensions Height x Width x Depth | mm | 550 x 765 x 285 | 734 x 870 x 373 | | Weight | kg | 32 | 32 | 32 | 50 | 50 | 50 | 50 | | Electrical Details | Power Supply | 1ph | 1ph | | Running Current - Cooling | A | 2.1 | 2.6 | 4.4 | 5.2 | 6.22 | 8.01 | 8.9 | | Max Fuse Size | A | 10 | 13 | 13 | 13 | 15 | 15 | 20 | | Interconnection Wiring Core / Cable size | 3+E / 1.5 | 3+E / 1.5 | 3+E / 1.5 | | Piping Connections Liquid / Gas | inches | 1/4 / 3/8 | 1/4 / 1/2 | 1/4 / 5/8 | | Pipework | Maximum Length m | 20 | 20 | 20 | 30 | 30 | 30 | 30 | | Maximum Vertical Rise | m | 20 | 20 | 20 | 20 | 20 | 20 | 20 | | Precharged to | m | 10 | 10 | 10 | 10 | 10 | 10 | 10 | | Additional Charge | g/m | 20 | 20 | 20 | 20 | 20 | 20 | 20 | | Holding Charge | kg | 0.76 | 0.76 | 0.76 | 1.1 | 1.15 | 1.15 | 1.7 | | Sound Pressure (Cooling) Nominal | dBA | 46 | 46 | 49 | 48 | 48 | 48 | 47 | | Sound Pressure (Heating) Nominal | dBA | 47 | 47 | 49 | 48 | 49 | 49 | 48 | | Sound Power (Cooling) | dBA | 59 | 58 | 61 | 62 | 62 | 63 | 66 | | Operating Range (Cooling) Min / Max | °CDB | -10 / 50 | -10 / 50 | -10 / 50 | -10 / 50 | -10 / 50 | -10 / 50 | -10 / 50 | | Operating Range (Heating) Min / Max | °CWB | -20 / 24 | -20 / 24 | -20 / 24 | -20 / 24 | -20 / 24 | -20 / 24 | -20 / 24 |
Dimensions
Dimensions
Dimensions
|