PRODUCTS
EShop-number
Password
Welcome to SK Sales
 

Comfora • Indoor & Outdoor Unit

F-Gas Certified

To be able to purchase this product we must hold a copy of your company F-Gas Certification on your account.

Links to accepted certification

REFCOM

F-Gas

Brand

  • Daikin

Product

  • Comfora - Indoor Unit & Outdoor Unit

Application

  • Cooling or Heating

Advantage

  • Onecta app: control your indoor from any location with an app, via your local network or internet.
  • Practically inaudible: the unit runs so quietly, you will almost forget it is there.
  • Voice command via Amazon Alexa or Google Assistant to control main functions such as set point, operation mode, fan speed, etc
  • Silver allergen removal and air purifying filter captures allergens such as pollen to ensure a steady supply of clean air
  • 3-D air flow combines vertical and horizontal auto swing to circulate a stream of warm or cool air right to the corners of even large spaces
  • The unit's compact dimensions makes it ideal for renovation projects, especially for above door installation
  • Choosing for an R-32 product, reduces the environmental impact with 68% compared to R-410A and leads directly to lower energy consumption thanks to its high energy efficiency
  • Seasonal efficiency values up to A++ in cooling and heating
  • Space saving contemporary wall mounted design

Function

  • Air-2-Air, Heatpump, Inverter Driven

Refrigerant

  • R32

Features

  • Onecta app (built in WiFi)

    Control your indoor climate from any location via smartphone or tablet

  • Econo mode

    Decreases power consumption so that other appliances that need large power consumption can be used. This function is also energy saving.

  • Energy saving during standby mode

    Current consumption is reduced by about 80% when operating on standby.

  • Night set mode

    Saves energy, by preventing overcooling or overheating during night time.

  • Fan only

    The unit can be used as fan, blowing air without heating or cooling.

  • Comfort mode

    Guarantees draught free operation by preventing that warm or cold air is directly blown on to the body.

  • Powerful mode

    Can be selected for rapid heating or cooling; after the powerful mode is turned off, the unit returns to the preset mode.

  • Auto cooling-heating changeover

    Automatically selects heating or cooling mode to achieve the set temperature.

  • Indoor unit silent operation

    "Silent" button on the remote control lowers the operation sound of the indoor unit by 3dB(A)

  • 3-D air flow

    Combines vertical and horizontal auto-swing to circulate a stream of warm or cool air right to the corners of even large spaces.

  • Vertical auto swing

    Possibility to select automatic vertical moving of the air discharge flaps for efficient air and temperature distribution throughout the room.

  • Horizontal auto swing

    Possibility to select automatic horizontal moving of the air discharge louvre, for uniform air flow and temperature distribution.

  • Auto fan speed

    Automatically selects the necessary fan speed to reach or maintain the set temperature.

  • Fan speed steps (5 steps)

    Allows to select up to the given number of fan speed.

  • Dry programme

    Allows humidity levels to be reduced without variations in room temperature.

  • Silver allergen removal and air purifying filter

    Captures allergens such as pollen and dust mites. The filter suppresses pollen and mites forr 99% or more.

  • Practically inaudible

    Practically inaudible: the unit runs so quietly, you will almost forget it is there.

  • Titanium apatite deodorising filter

    Decomposes bothersome odours of for example tobacco and pets

  • Air filter

    Removes airborne dust particles to ensure a steady supply of clean air.

  • 24 hour timer

    Can be set to start operation anytime during a 24 hour period

  • Infrared remote control

    Starts, stops and regulates the air conditioner from a distance.

  • Auto-restart

    The unit restarts automatically at the original settings after power failure.

  • Self diagnosis

    Simplifies maintenance by indicating system faults or operating anomalies.

Operating tips

Keep fan running when reaching set point (FTXP Fan Motor IR Commands)

Applicable outdoor units

  • Type RXP 20/25/35/50/60/71 N
  • Type 2MXM40A/2MXM50A/2MXM68A (ONLY FTXP 20/25/35 N)
  • Type 3MXM52A/3MXM68A (ONLY FTXP 20/25/35 N)

Applicable controller

FTXP 20,25,35 N = ARC480A78
FTXP 50,60,71 N = ARC480A53

Remote Controller

Accessories

  • KRP980B1 - Wire harness for S21 port for all marked (*) options - required for FTXP20,25,35 N only
  • BRC073* - Optional wired remote controller BRC1E53A style - Connection cable required
  • BRCW901A03 - 3m connection cable for BRC073
  • BRCW901A08 - 8m connection cable for BRC073
  • KRP413A1S - Adaptor PCB for remote on/off control - constant/pulse contact
  • KRP928A2S* - Adaptor PCB for interface to Daikin centralised control systems
  • RTD-RA* - Adapter PCB for Modbus connection and/or extended system functions

Video 1

Specifications

Indoor UnitsFTXP20NFTXP25NFTXP35NFTXP50NFTXP60NFTXP71N
CapacityUK Total Cooling kW1.952.443.424.895.866.93
UK Sensible Cooling kW1.691.942.493.4244.73
Nominal Cooling kW22.53.5567.1
Nominal Heating kW2.534678.2
Seasonal Efficiency (EN14825) COOLINGEnergy LabelA++A++A++A++A++A++
Pdesign kW22.53.5567.1
SEER7.27.27.27.36.826.2
Annual Energy Consumption kWh97121170240308401
Seasonal Efficiency (EN14825) HEATINGEnergy LabelA++A++A++A+A+A+
Pdesign kW2.22.42.84.64.86.2
SCOP4.654.614.644.44.14.01
Annual Energy Consumption kWh663728845146316382166
Air Flow Rate (Cooling) High / Med / Low / Silent m3/sec0.158 / 0.123 /
0.093 / 0.070
0.162 / 0.128 /
0.097 / 0.070
0.192 / 0.138 /
0.105 / 0.075
0.272 / 0.233 /
0.192 / 0.138
0.280 / 0.240 /
0.197 / 0.153
0.280 / 0.240 /
0.197 / 0.168
DimensionsHeight mm286286286295295295
Width mm770770770990990990
Depth mm225225225263263263
Weight kg8.58.5913.513.513.5
RAL ColourRAL 9002RAL 9002RAL 9002RAL 9002RAL 9002RAL 9002
Sound Pressure (Cooling) High / Med / Low / Silent dBA39 / 33 / 25 / 1940 / 33 / 26 / 1943 / 34 / 27 / 2043 / 39 / 34 / 2745 / 41 / 36 / 3046 / 42 / 37 / 32
Sound Pressure (Heating) High / Med / Low / Silent dBA39 / 34 / 28 / 2140 / 34 / 28 / 2140 / 35 / 29 / 2142 / 38 / 33 / 3044 / 40 / 35 / 3245 / 41 / 36 / 33
Sound Power (Cooling) dBA555558596062

Specifications

Outdoor UnitsRXP20NRXP25NRXP35NRXP50NRXP60NRXP71N
DimensionsHeight x Width x Depthmm556 X 740 X 343556 X 740 X 343556 X 740 X 343734 x 954 x 401734 x 954 x 401734 x 954 x 401
Weight kg242424465050
Electrical DetailsPower Supply1ph1ph1ph1ph1ph1ph
Maximum Input Current A (MCA)7.997.999.214.515.715.7
Max Fuse Size A161616202020
Interconnection Wiring Core / Cable Size3+E / 1.53+E / 1.53+E / 1.53+E / 1.53+E / 1.53+E / 1.5
Piping ConnectionsLiquid / Gasinches (mm)1/4 (6.4) / 3/8 (9.5)1/4 (6.4) / 3/8 (9.5)1/4 (6.4) / 3/8 (9.5)1/4 (6.4) / 1/2 (12.7)1/4 (6.4) / 1/2 (12.7)1/4 (6.4) / 1/2 (12.7)
PipeworkMaximum Length m202020303030
Maximum Vertical Rise m121212202020
Precharged to m101010101010
Additional charge g/m202020202020
Holding charge kg0.550.550.70.91.151.15
Sound Pressure (Cooling)NominaldBA464648474952
Sound Pressure (Heating)NominaldBA474748494952
Sound Power (Cooling) dBA616162616366
Operating Range (Cooling)Min / Max°CDB-10 / 48-10 / 48-10 / 48-10 / 48-10 / 48-10 / 48
Operating Range (Heating)Min / Max°CWB-15 / 18-15 / 18-15 / 18-15 / 18-15 / 18-15 / 18
Air Flow Rate (Cooling)Nominalm3/sec0.460.460.470.6830.7580.758