PRODUCTS
EShop-number
Password
Welcome to SK Sales
 

Sensira • Indoor & Outdoor Unit

F-Gas Certified

To be able to purchase this product we must hold a copy of your company F-Gas Certification on your account.

Links to accepted certification

REFCOM

F-Gas

Brand

  • Daikin

Product

  • Sensira - Indoor Unit & Outdoor Unit

Application

  • Cooling or Heating

Advantage

  • Seasonal efficiency values up to A++ in cooling
  • Online controller (optional): control your indoor from any location with an app, via your local network or internet and keep an overview on your energy consumption
  • Quiet in operation down to 21 dBA
  • Choosing for an R-32 product, reduces the environmental impact with 68% compared to R-410A and leads directly to lower energy consumption thanks to its high energy efficiency

Function

  • Air-2-Air, Heatpump, Inverter Driven

Refrigerant

  • R32

Features

  • Seasonal efficiency values up to A++ in cooling
  • Onecta app (optional): control your indoor from any location with an app, via your local network or internet.
  • Quiet in operation down to 21 dBA
  • Choosing for an R-32 product, reduces the environmental impact with 68% compared to R-410A and leads directly to lower energy consumption thanks to its high energy efficiency
  • Onecta app (optional)

    Control your indoor climate from any location via smartphone or tablet

  • Econo mode (25, 35 class)

    Decreases power consumption so that other appliances that need large power consumption can be used. This function is also energy saving.

  • Energy saving during standby mode (25, 35 class)

    Current consumption is reduced by about 80% when operating on standby.

  • Fan only

    The unit can be used as fan, blowing air without heating or cooling.

  • Comfort mode (25, 35 class)

    Guarantees draught free operation by preventing that warm or cold air is directly blown on to the body.

  • Powerful mode

    Can be selected for rapid heating or cooling; after the powerful mode is turned off, the unit returns to the preset mode.

  • Auto cooling-heating changeover

    Automatically selects heating or cooling mode to achieve the set temperature.

  • Indoor unit silent operation

    "Silent" button on the remote control lowers the operation sound of the indoor unit by 3dB(A)

  • Vertical auto swing

    Possibility to select automatic vertical moving of the air discharge flaps for efficient air and temperature distribution throughout the room.

  • Auto fan speed

    Automatically selects the necessary fan speed to reach or maintain the set temperature.

  • Fan speed steps (5 steps)

    Allows to select up to the given number of fan speed.

  • Dry programme

    Allows humidity levels to be reduced without variations in room temperature.

  • Air filter

    Removes airborne dust particles to ensure a steady supply of clean air.

  • 24 hour timer

    Can be set to start operation anytime during a 24 hour period

  • Infrared remote control

    Starts, stops and regulates the air conditioner from a distance.

  • Auto-restart

    The unit restarts automatically at the original settings after power failure.

  • Self diagnosis

    Simplifies maintenance by indicating system faults or operating anomalies.

Operating tips

Keep fan running when reaching set point (FTXF Fan Motor IR Commands)

Applicable outdoor units

  • Type RXF 20/25/35/42/50/60/71 E/D

Applicable controller

ARC470A1

Accessories

  • KRP980B1 - Wire harness for S21 port for all marked (*) options - required for FTXF-E only
  • BRC073* - Optional wired remote controller BRC1E53A style - Connection cable required
  • BRCW901A03 - 3m connection cable for BRC073
  • BRCW901A08 - 8m connection cable for BRC073
  • BRP069B45 - Wifi adaptor for connection to on-line controller FTXF-D
  • BRP069C47 - Wifi adaptor for connection to on-line controller FTXF-E

Video 1

Specifications

Indoor unit  FTXF20E25E35E42E
DimensionsUnitHeightxWidthxDepthmm286 x770 x225
WeightUnit  kg88.59
Air filterType    
FanAir flow rateCoolingSilent operation/Low/ Medium/Highm³/min4.3 /6.0 /8 /9.84.3 /6.2 /8 /10.04.4 /6.4 /8 /11.54.9 /6.9 /9 /12.6
  HeatingSilent operation / Low
/ Medium / High
m³/min5.3 / 6.2 / 8.3
/ 10.4
5.3 / 6.4 / 8.4
/ 10.4
5.3 / 6.5 / 8.6
/ 11.9
5.2 / 6.7 / 8.8
/ 12.8
Sound power levelCooling  dBA535459
Heating  dBA555659
Sound pressure levelCoolingSilent operation/Low/HighdBA20 /25 /3920 /26 /4020 /27 /4322 /30 /45
HeatingSilent operation/Low/HighdBA21 /28/3921 /28/4021 /29 /4022 /28 /44
Control systemsInfrared remote control 
Wired remote control 
Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; equivalent piping length: 5m; level difference: 0m. Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 5m (horizontal). See separate drawing for electrical data

Specifications

Indoor unit  FTXF50D60D71D
DimensionsUnitHeightxWidthxDepthmm295 x990 x263
WeightUnit kg13.5
Air filterType  Removable / washable
FanAir flow rateCooling Silent operation/
Low/Medium/ High
m³/min10.5 /11.9 /14.4
/16.8
10.7 /12.2 /14.8 /17.3
Heating Silent operation/
Low/Medium/ High
m³/min10.7 /12.2 /14.8
/17.3
11.3 /12.8 /15.8 /17.9
Sound power levelCooling dBA596062
Heating dBA6162
Sound pressure levelCoolingSilent operation/Low/HighdBA31 /34 /4333 /36 /4534 /37 /46
HeatingSilent operation/Low/HighdBA30 /33 /4232 /35 /4433 /36 /45
Control systemsInfrared remote controlARC470A1
Wired remote controlBRC073A1
Piping connections Drain18

Specifications

Outdoor unit RXF20E25E35E42E
DimensionsUnitHeightxWidthxDepthmm556 x740 x343
WeightUnitkg2428
Sound power levelCoolingNom.dBA6061
 HeatingNom.dBA6062
Sound pressure levelCoolingNom./HighdBA-/46-/48
HeatingNom./HighdBA-/47-/48
Operation rangeCoolingAmbient Min.~Max.°CDB-10 ~48
HeatingAmbient Min.~Max.°CWB-15 ~18
RefrigerantType 
GWP675
Chargekg/
TCO2Eq
0.420 /0.2800.550 /0.3700.750 /0.510
Piping connectionsLiquidODmm1/4
 GasODmm3/8
 PipingOU - IU Max.m20
 length 
 Additional refrigerant chargekg/m 
 LevelIU - OU Max.m12
 difference 
Power supplyPhase/Frequency/VoltageHz/V 
Current - 50HzMaximum fuse amps (MFA)A16
Contains fluorinated greenhouse gases. See separate drawing for electrical data. See separate drawing for operation range

Specifications

Outdoor unit  RXF50D60D71D
DimensionsUnitHeightxWidthxDepthmm734 x870 x373
WeightUnit kg4650
Sound power level Cooling-
Sound pressure
level
CoolingLow/Nom./HighdBA-/47 /--/49 /--/52 /-
HeatingLow/Nom./HighdBA-/49 /--/52 /-
Operation rangeCoolingAmbient Min.~Max.°CDB-10 ~48
HeatingAmbient Min.~Max.°CWB-15 ~18

Specifications

Efficiency data FTXF + RXF20E + 20E25E + 25E35E + 35E42E + 42E
Cooling capacityMin./Nom./Max.kW1.3 /2.00 /2.41.3 /2.50 /2.81.3 /3.30 /3.81.4 /4.20 /4.3
Heating capacityMin./Nom./Max.kW1.30 /2.40 /3.301.30 /2.80 /3.701.30 /3.50 /4.401.40 /4.60 /5.00
Power inputCooling Min./Nom./Max.kW0.31 /0.592 /0.720.31 /0.772 /1.050.31 /1.00 /1.400.31 /1.27 /1.50
Heating Min./Nom./Max.kW0.25 /0.640 /0.950.25 /0.750 /1.110.25 /0.940 /1.500.25 /1.24 /1.40
Space coolingEnergy efficiency classA++
Capacity PdesignkW22.53.54.2
SEER6.5
Annual energy consumptionkWh/a108135188226
Space heating (Average climate)Energy efficiency classA+
Capacity PdesignkW2.22.42.63.3
SCOP/A4.24.3
Annual energy consumptionkWh/a7338018671075
Nominal efficiencyEER3.383.243.3
COP3.753.733.723.71
Annual energy consumptionkWh-
Energy labeling Directive Cooling/HeatingA/A
Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. Data for high efficiency series, Eurovent certified. Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. Data for standard efficiency series.Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. See separate drawing for operation range

Specifications

Efficiency data FTXF + RXF50D + 50D60D + 60D71D + 71D
Cooling capacityMin./Nom./Max. kW1.70 /5.00
/6.00
1.70 /6.00 /7.002.30 /7.10 /7.30
Heating capacityMin./Nom./Max. kW1.70 /6.00 /7.701.70 /6.40
/8.00
2.30 /8.20
/9.00
Power inputCoolingMin./Nom./Max.kW-/1.50 /--/1.85 /--/2.77 /-
HeatingMin./Nom./Max.kW-/1.62 /--/1.63 /--/2.21 /-
Space coolingEnergy efficiency classA++A
CapacityPdesignkW567.1
SEER6.216.155.15
Annual energy consumptionkWh/a282342483
Space heating (Average climate)Energy efficiency classA+A
CapacityPdesignkW4.64.86.2
SCOP/A4.063.81
Annual energy consumptionkWh/a158516542275
Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. Data for high efficiency series, Eurovent certified | Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. Data for standard efficiency series | Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. | Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. | See separate drawing for operation range

Dimensions

Dimensions

Mobile WebsiteAbout UsDisclaimerPrivacy policyCookie policy

Requesting information. Please wait a moment...