To be able to purchase this product we must hold a copy of your company F-Gas Certification on your account.
Links to accepted certification
Keep fan running when reaching set point
(FTXF Fan Motor IR Commands)
Specifications
|
| Dimensions | Unit | HeightxWidthxDepth | mm | 286 x770 x225 | | Weight | Unit | | | kg | 8 | 8.5 | 9 | | Air filter | Type | | | | | | Fan | Air flow rate | Cooling | Silent operation/Low/ Medium/High | m³/min | 4.3 /6.0 /8 /9.8 | 4.3 /6.2 /8 /10.0 | 4.4 /6.4 /8 /11.5 | 4.9 /6.9 /9 /12.6 | | | | Heating | Silent operation / Low
/ Medium / High | m³/min | 5.3 / 6.2 / 8.3
/ 10.4 | 5.3 / 6.4 / 8.4
/ 10.4 | 5.3 / 6.5 / 8.6
/ 11.9 | 5.2 / 6.7 / 8.8
/ 12.8 | | Sound power level | Cooling | | | dBA | 53 | 54 | 59 | | Heating | | | dBA | 55 | 56 | 59 | | Sound pressure level | Cooling | Silent operation/Low/High | dBA | 20 /25 /39 | 20 /26 /40 | 20 /27 /43 | 22 /30 /45 | | Heating | Silent operation/Low/High | dBA | 21 /28/39 | 21 /28/40 | 21 /29 /40 | 22 /28 /44 | | Control systems | Infrared remote control | | | Wired remote control | | | Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; equivalent piping length: 5m; level difference: 0m. Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 5m (horizontal). See separate drawing for electrical data |
Specifications
|
| Dimensions | Unit | HeightxWidthxDepth | mm | 295 x990 x263 | | Weight | Unit | | kg | 13.5 | | Air filter | Type | | | Removable / washable | | Fan | Air flow rate | Cooling Silent operation/
Low/Medium/ High | m³/min | 10.5 /11.9 /14.4
/16.8 | 10.7 /12.2 /14.8 /17.3 | Heating Silent operation/
Low/Medium/ High | m³/min | 10.7 /12.2 /14.8
/17.3 | 11.3 /12.8 /15.8 /17.9 | | Sound power level | Cooling | | dBA | 59 | 60 | 62 | | Heating | | dBA | 61 | 62 | | Sound pressure level | Cooling | Silent operation/Low/High | dBA | 31 /34 /43 | 33 /36 /45 | 34 /37 /46 | | Heating | Silent operation/Low/High | dBA | 30 /33 /42 | 32 /35 /44 | 33 /36 /45 | | Control systems | Infrared remote control | ARC470A1 | | Wired remote control | BRC073A1 | | Piping connections Drain | 18 |
Specifications
|
| Dimensions | Unit | HeightxWidthxDepth | mm | 556 x740 x343 | | Weight | Unit | kg | 24 | 28 | | Sound power level | Cooling | Nom. | dBA | 60 | 61 | | | Heating | Nom. | dBA | 60 | 62 | | Sound pressure level | Cooling | Nom./High | dBA | -/46 | -/48 | | Heating | Nom./High | dBA | -/47 | -/48 | | Operation range | Cooling | Ambient Min.~Max. | °CDB | -10 ~48 | | Heating | Ambient Min.~Max. | °CWB | -15 ~18 | | Refrigerant | Type | | | GWP | 675 | | Charge | kg/
TCO2Eq | 0.420 /0.280 | 0.550 /0.370 | 0.750 /0.510 | | Piping connections | Liquid | OD | mm | 1/4 | | | Gas | OD | mm | 3/8 | | | Piping | OU - IU Max. | m | 20 | | | length | | | | Additional refrigerant charge | kg/m | | | | Level | IU - OU Max. | m | 12 | | | difference | | | Power supply | Phase/Frequency/Voltage | Hz/V | | | Current - 50Hz | Maximum fuse amps (MFA) | A | 16 | | Contains fluorinated greenhouse gases. See separate drawing for electrical data. See separate drawing for operation range |
Specifications
|
| Dimensions | Unit | HeightxWidthxDepth | mm | 734 x870 x373 | | Weight | Unit | | kg | 46 | 50 | | Sound power level Cooling | - | Sound pressure
level | Cooling | Low/Nom./High | dBA | -/47 /- | -/49 /- | -/52 /- | | Heating | Low/Nom./High | dBA | -/49 /- | -/52 /- | | Operation range | Cooling | Ambient Min.~Max. | °CDB | -10 ~48 | | Heating | Ambient Min.~Max. | °CWB | -15 ~18 |
Specifications
|
| Cooling capacity | Min./Nom./Max. | kW | 1.3 /2.00 /2.4 | 1.3 /2.50 /2.8 | 1.3 /3.30 /3.8 | 1.4 /4.20 /4.3 | | Heating capacity | Min./Nom./Max. | kW | 1.30 /2.40 /3.30 | 1.30 /2.80 /3.70 | 1.30 /3.50 /4.40 | 1.40 /4.60 /5.00 | | Power input | Cooling Min./Nom./Max. | kW | 0.31 /0.592 /0.72 | 0.31 /0.772 /1.05 | 0.31 /1.00 /1.40 | 0.31 /1.27 /1.50 | | Heating Min./Nom./Max. | kW | 0.25 /0.640 /0.95 | 0.25 /0.750 /1.11 | 0.25 /0.940 /1.50 | 0.25 /1.24 /1.40 | | Space cooling | Energy efficiency class | A++ | | Capacity Pdesign | kW | 2 | 2.5 | 3.5 | 4.2 | | SEER | 6.5 | | Annual energy consumption | kWh/a | 108 | 135 | 188 | 226 | | Space heating (Average climate) | Energy efficiency class | A+ | | Capacity Pdesign | kW | 2.2 | 2.4 | 2.6 | 3.3 | | SCOP/A | 4.2 | 4.3 | | Annual energy consumption | kWh/a | 733 | 801 | 867 | 1075 | | Nominal efficiency | EER | 3.38 | 3.24 | 3.3 | | COP | 3.75 | 3.73 | 3.72 | 3.71 | | Annual energy consumption | kWh | - | | Energy labeling Directive Cooling/Heating | A/A | | Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. Data for high efficiency series, Eurovent certified. Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. Data for standard efficiency series.Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. See separate drawing for operation range |
Specifications
|
| Cooling capacity | Min./Nom./Max. | | kW | 1.70 /5.00
/6.00 | 1.70 /6.00 /7.00 | 2.30 /7.10 /7.30 | | Heating capacity | Min./Nom./Max. | | kW | 1.70 /6.00 /7.70 | 1.70 /6.40
/8.00 | 2.30 /8.20
/9.00 | | Power input | Cooling | Min./Nom./Max. | kW | -/1.50 /- | -/1.85 /- | -/2.77 /- | | Heating | Min./Nom./Max. | kW | -/1.62 /- | -/1.63 /- | -/2.21 /- | | Space cooling | Energy efficiency class | A++ | A | | Capacity | Pdesign | kW | 5 | 6 | 7.1 | | SEER | 6.21 | 6.15 | 5.15 | | Annual energy consumption | kWh/a | 282 | 342 | 483 | | Space heating (Average climate) | Energy efficiency class | A+ | A | | Capacity | Pdesign | kW | 4.6 | 4.8 | 6.2 | | SCOP/A | 4.06 | 3.81 | | Annual energy consumption | kWh/a | 1585 | 1654 | 2275 | | Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. Data for high efficiency series, Eurovent certified | Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. Data for standard efficiency series | Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. | Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. | See separate drawing for operation range |
Dimensions
Dimensions
|