To be able to purchase this product we must hold a copy of your company F-Gas Certification on your account.
Links to accepted certification
Daikin Altherma high temperature split
Floor standing air to water heat pump for heating and hot water
ETVH16SU18E6V - Heating Only Model
ETVH16SU23E6V - Heating Only Model
Technical data
|
|
|
|
|
|
|
|
| Function | Heating only | Heating only | | Casing | Colour | White | White | | Material | Resin + Sheet Metal | Resin + Sheet Metal | | Dimensions | Height x Width x Depth | mm | 1,650 x 595 x 625 | 1,850 x 595 x 625 | Weight
Operating range | Unit / Packed Unit | kg | 109 / 126 | 118 / 135 | | Heating | Min-Max. | 10°C - 63°C | 10°C - 63°C | | | DHW | Max. | 63°C [1] | 63°C [1] | | Sound power level | Nom. | dBA | 44 | 44 | | Sound pressure level | Nom. | dBA | 30 | 30 | | Tank | Water Volume | Litres | 180 | 230 | | Maximum water pressure | bar | 10 | 10 | | Material | Stainless steel (EN 1.4521) | Stainless steel (EN 1.4521) | | Load profile EN16147 | L | XL | | Standing heat loss | W | 56 | 73 | | Energy efficiency rating | C | B | | Standing heat loss @ 45K dT kWh/24h | 1.8 | 1.4 | | Hydraulic characteristics | Water connections Indoor
/ outdoor | inch | G 1” (female) | G 1” (female) | Water connections DHW
/ Recirc | inch | G 3/4” (female) | G 3/4” (female) | | Water connections Space heating | inch | G 1” (female) | G 1” (female) | | Minimum water volume | | litres | 20 | 20 | | Minimum flow rate | | l/min | 20 | 20 | | Backup heater power supply [2] | Phase | | 1~ / 3~ | 1~ / 3~ | | | Frequency | Hz | 50 | 50 | | | Voltage | V | 230 | 230 | | | Maximum capacity | kW | 6 (2 step) [3] | 6 (2 step) [3] | | | Maximum running current | A | 26 | 26 | | | Recommended fuse rating | A | 20 [4] | 20 [4] | [1] Tank temperature up to 75°C possible with booster heater only operation (if available in the system).
[2] Power supply is for backup heater only. Indoor unit switch box and circulation pump are supplied via the outdoor unit.
[3] Backup heater steps electronically setup on the indoor unit interface.
[4] 4 pole 20A curve 400V tripping class C (refer to wiring diagram) |
Accessories
|
| BRC1HHDW | Madoka Heating - White | | BRC1HHDS | Madoka Heating - Silver | |
| BRC1HHDK | Madoka Heating - Black | | AFVALVE1 | Anti-freeze valve for glycol free systems (two required per heat pump) | |
| EKPCCAB4 | PC cable – to upload field settings from PC to unit | | EKRSC1 | Optional remote temperature sensor for outdoor unit* | | KRCS01-1 | Optional remote temperature sensor for indoor unit* | | EKRP1HBA | Optional PCB kit for remote alarm monitoring, run and fault indication and bivalent operation | |
| EKRP1AHT | Optional PCB for upto 4 digital inputs for power limitation | | EKUMBPART | Third party tank connection kit for dry pocket (contains 3 way valve, tank sensor and contactor) | | BRP069A71 | Residential Controller App | | K.ELECMETV | Electric meter for domestic RHI - Single-phase (Metering for performance compliant)
MID Class A electric meter to measure the electricity consumption of the Daikin Altherma heat pump | | K.ELECMETW | Electric meter for domestic RHI - Three-phase (Metering for performance compliant)
MID Class A electric meter to measure the electricity consumption of the Daikin Altherma heat pump | | EKCC8-W | Sequence Controller | | DCOM-LT/IO | Daikin Altherma I/O (Sequence Controller/Voltage/ Resistance/Smart Grid) Gateway | | DCOM-LT/MB | Daikin Altherma Modbus Gateway |
Pump Curve
Installation
|