Technical data
|
|
|
|
|
|
| Function | Heating Only | Heating Only | Reversible | Reversible | | Dimensions | Height x Width x Depth | mm | 840 x 440 x 390 | 840 x 440 x 390 | 840 x 440 x 390 | 840 x 440 x 390 | | Operating range | Heating | °C | +18 to +70 | +18 to +70 | +18 to +70 | +18 to +70 | | Cooling °C | - | - | +5 to +25 | +5 to +25 | | Domestic hot water [1] °C | +10 to 75 | +10 to 75 | +10 to 75 | +10 to 75 | | Pump | No. of speeds | | Inverter controlled | Inverter controlled | Inverter controlled | Inverter controlled | | Expansion vessel volume litres | 10 | 10 | 10 | 10 | | Minimum water volume litres | 20 | 20 | 20 | 20 | | Minimum flow rate l/min | 25 | 25 | 25 | 25 | | Water connections inch | 1” (female) | 1” (female) | 1” (female) | 1” (female) | | Backup heater power supply [2] | Phase | 1~ / 3~ | 3~ | 1~ / 3~ | 3~ | | Frequency | Hz | 50 | 50 | 50 | 50 | | Voltage V | 230 | 400 | 230 | 400 | | Maximum capacity [3] kW | 6 (2 step) | 9 (2 step) | 6 (2 step) | 9 (2 step) | | | Maximum running current | A | 26 | 13 | 26 | 13 | | Recommended fuse rating [4] A | 20 | 20 | 20 | 20 | [1] Tank temperature up to 75°C possible with backup heater only operation (or booster, if available in the system).
[2] Power supply is for backup heater only. Indoor unit switch box and circulation pump are supplied via the outdoor unit.
[3] Backup heater steps electronically setup on the indoor unit interface.
[4] 4 pole 20A curve 400V tripping class C (refer to wiring diagram) |
Accessories
|
| BRC1HHDW | Madoka Heating - White | | BRC1HHDS | Madoka Heating - Silver | |
| BRC1HHDK | Madoka Heating - Black | | AFVALVE1 | Anti-freeze valve for glycol free systems (two required per heat pump) | |
| EKPCCAB4 | PC cable – to upload field settings from PC to unit | | EKRSC1 | Optional remote temperature sensor for outdoor unit* | | KRCS01-1 | Optional remote temperature sensor for indoor unit* | | EKRP1HBA | Optional PCB kit for remote alarm monitoring, run and fault indication and bivalent operation | |
| EKRP1AHT | Optional PCB for upto 4 digital inputs for power limitation | | UK.FF600H150 | Pair of flexi-feet for mounting outdoor unit, 150mm tall** | | UK.CBR2XXL-B | Wall bracket for outdoor unit (250 Kg, 780mm long arm, 2 arms, black) | |
|
| UK.DT4 | Condensate drip tray (1420 x 550 x 50mm) | | K.DTFB | Floor bracket kit to mount drip tray to pair flexi feet or wall bracket | |
|
| K.HOSE750 | Pair of flexible hoses (Length 750mm, 19mm tough PVC coated insulation, 1" FBSP x 28mm compression) | | K.HOSE750EL | Pair of flexible hoses with elbow (Length 750mm, 19mm tough PVC coated insulation, 1" FBSP x 28mm compression) | | EKUMBPART | Third party tank connection kit for dry pocket (contains 3 way valve, tank sensor and contactor) | | BRP069A62 | Residential Controller App | | K.ELECMETV | Electric meter for domestic RHI - Single-phase (Metering for performance compliant)
MID Class A electric meter to measure the electricity consumption of the Daikin Altherma heat pump | | K.ELECMETW | Electric meter for domestic RHI - Three-phase (Metering for performance compliant)
MID Class A electric meter to measure the electricity consumption of the Daikin Altherma heat pump | | EKCC8-W | Sequence Controller | | DCOM-LT/IO | Daikin Altherma I/O (Sequence Controller/Voltage/ Resistance/Smart Grid) Gateway | | DCOM-LT/MB | Daikin Altherma Modbus Gateway |
Pump Curve
|