To be able to purchase this product we must hold a copy of your company F-Gas Certification on your account.
Links to accepted certification
EHVH04SU18E6V - Heating Only Model (Intergrated 180L Tank)
EHVH08SU18E6V - Heating Only Model (Intergrated 180L Tank)
EHBX04SU23E6V - Heating & Cooling Model (Intergrated 230L Tank)
EHBX08SU23E6V - Heating & Cooling Model (Intergrated 230L Tank)
Technical data
|
|
|
|
|
| Function | Heating only | Heating only | Heating only | Heating only | | Casing | Colour | White | White | White | White | | | Material | Resin + Sheet Metal | Resin + Sheet Metal | Resin + Sheet Metal | Resin + Sheet Metal | | Dimensions | Height x Width x Depth | mm | 1,650 x 595 x 625 | 1,850 x 595 x 625 | 1,650 x 595 x 625 | 1,850 x 595 x 625 | |
| Weight | Unit / Packed Unit | kg | 119 / 135 | 128 / 144 | 119 / 135 | 128 / 144 | | Operating range | Heating | Min-Max. | 18°C - 65°C | 18°C - 65°C | 18°C - 65°C | 18°C - 65°C | | DHW | Max. | 60°C [1] | 60°C [1] | 60°C [1] | 60°C [1] | | Sound power level | Nom. | dBA | 42 | 42 | 42 | 42 | | Sound pressure level | Nom. | dBA | 28 | 28 | 28 | 28 | | Tank | Water Volume | Litres | 180 | 230 | 180 | 230 | | Maximum water pressure | bar | 10 | 10 | 10 | 10 | | Material | Stainless steel (EN 1.4521) | Stainless steel (EN 1.4521) | Stainless steel (EN 1.4521) | Stainless steel (EN 1.4521) | | Load profile EN16147 | L | XL | L | XL | | Standing heat loss | W | 56 | 73 | 56 | 73 | | Energy efficiency rating | A+ | A+ | A+ | A+ | | Standing heat loss @ 45K dT kWh/24h | 1.4 | 1.8 | 1.4 | 1.8 | | Hydraulic characteristics | Water connections DHW
/ Recirc | inch | G 3/4” (female) | G 3/4” (female) | G 3/4” (female) | G 3/4” (female) | | Water connections Space heating | inch | G 1” (female) | G 1” (female) | G 1” (female) | G 1” (female) | | Minimum water volume | | litres | 20 | 20 | 20 | 20 | | Minimum flow rate | | l/min | 12 | 12 | 12 | 12 | | Backup heater power supply [2] | Phase | 1~ / 3~ | 1~ / 3~ | 1~ / 3~ | 1~ / 3~ | | Frequency | Hz | 50 | 50 | 50 | 50 | | Voltage | V | 230 | 230 | 230 | 230 | | Maximum capacity | kW | 6 (2 step) [3] | 6 (2 step) [3] | 6 (2 step) [3] | 6 (2 step) [3] | | Maximum running current | A | 26 | 26 | 26 | 26 | | Recommended fuse rating | A | 20 [4] | 20 [4] | 20 [4] | 20 [4] | [1] Tank temperature up to 70°C possible with booster heater only operation (if available in the system).
[2] Power supply is for backup heater only. Indoor unit switch box and circulation pump are supplied via the outdoor unit.
[3] Backup heater steps electronically setup on the indoor unit interface.
[4] 4 pole 20A curve 400V tripping class C (refer to wiring diagram). |
|