PRODUCTS
EShop-number
Password
Welcome to SK Sales
 

ERGA-EVA • Low Temperature R-Split - Outdoor

F-Gas Certified

To be able to purchase this product we must hold a copy of your company F-Gas Certification on your account.

Links to accepted certification

REFCOM

F-Gas

Application

Daikin Altherma low temperature split

Features

  • Combining with R-32 Bluevolution technology, reduces environmental impact with 68% compared to R-410A, leads directly to lower energy consumption thanks to its high energy efficiency and has up to lower 16% refrigerant charge
  • Outdoor unit extracts heat from the outdoor air, even at -25°C
  • WLAN cartridge included
  • Daikin Residential Controller (optional) Control your indoor climate from any location via smartphone or tablet
  • Online controller Control your indoor unit from any lcoation via smart phone, laptop, pc, tablet or touch screen
  • Guaranteed operation down to -25°C Daikin units are suitable for all climates, even withstanding severe winter conditions with an operation range down to -25°C

Refrigerant

R32

Applicable indoor units

Wall Hung
  • EHBH04E6V
  • EHBH08E6V
  • EHBX04E6V
  • EHBX08E6V
Intergrated
  • EHVH04SU18E6V
  • EHVH04SU23E6V
  • EHVH08SU18E6V
  • EHVH08SU23E6V

Video

Technical data

Outdoor UnitsSingle Phase
ERGA04EVAERGA06EVAERGA08EVA
Description4kW6kW8kW
DimensionsHeight x Width x Depthmm740 x 884 x 388740 x 884 x 388740 x 884 x 388
Weight kg58.558.558.5
Nominal capacityHeating (a/b) kW4.30 / 4.606.00 / 5.907.50 / 7.80
Cooling (c/d) kW5.56 / 4.375.96 / 4.876.25 / 5.35
Nominal inputHeating (a/b) kW0.85 / 1.261.24 / 1.691.63 / 2.23
Cooling (c/d) kW0.94 / 1.141.06 / 1.331.16 / 1.51
Seasonal space heating efficiency*Space heating (Average climate) 35°CClassA+++A+++A+++
Efficiency176176179
SCOP4.484.474.56
Space heating (Average climate) 55°CClassA++A++A++
Efficiency127127128
SCOP3.263.253.27
COPHeating (a/b) 5.10 / 3.654.85 / 3.504.60 / 3.50
EERCooling (c/d) 5.94 / 3.845.61 / 3.675.40 / 3.54
Operation rangeHeating°C-25~25-25~25-25~25
Cooling °C10~4310~4310~43
Hot water °C-25~35-25~35-25~35
Sound pressure / power levelHeating dBA44 / 5847 / 6049 / 62
Cooling dBA48 / 6149 / 6250 / 62
Refrigerant chargeR-32kg1.51.51.5
Piping connectionsLiquid inch1/4 ”1/4 ”1/4 ”
Gas inch5/8 ”5/8 ”5/8 ”
Maximum piping length OU to IU m303030
Power supply1-phase / 230V / 50Hz1-phase / 230V / 50Hz1-phase / 230V / 50Hz
Recommended fuses A161616
Nominal capacity and nominal input tested according to EN 14511
Heating (a): Ambient air temperature 7°CDB and leaving water temperature 35°C (A7/W35). Heating (b): Ambient air temperature 7°CDB and leaving water temperature 45°C (A7/W45) Cooling (c): Ambient air temperature 35°C and leaving water temperature 18°C (A35/W18). Cooling (d): Ambient air temperature 35°C and leaving water temperature 7°C (A35/W7) Sound pressure / power measured according to EN 12102 under conditions of EN 14825